18
̶
 ① Set the function selector switch to the "
V" position. “DC"
should be shown on the upper left corner of the display.
 ② Slide the terminal cover to the left to disclose the V/Ω and COM
terminals. Plug the red test lead into the V/Ω terminal and the
black test lead into COM terminal.
 ③ Connect the tip of the red and black test leads to the positive (+)
and negative (-) sides of the circuit under test respectively. Take
the reading on the display. If the connection is reversed, the
display indicates the "-" sign.
6-4 AC Voltage Measurements
DANGER
Never use the instrument on a circuit above 750VAC. This may
cause electrical shock hazard and damage to the instrument or
the circuit under test.
Do not make measurement with the battery compartment cover
removed.
Keep your fingers and hands behind the barrier during
measurement.
 ① Set the function selector switch to the " V" position. "AC"
should be shown on the upper left corner of the display.
 ② Slide the terminal cover to the left to disclose the V/Ω and COM
terminals. Plug the red test lead into V/Ω terminal and the black
test lead into the COM terminal.
Red test lead
Black
test lead