オートレンジ デジタル マルチメータ・AUTO RANGE DIGITAL MULTIMETER
KYORITSU ELECTRICAL INSTRUMENTS
WORKS,LTD.,
取扱説明書
INSTRUCTION MANUAL
Vedere la pagina 0
1 2 3 4 5 6 ... 11 12

Sommario

Pagina 1 - KEW 1012

KEW 1012オートレンジ デジタル マルチメータ・AUTO RANGE DIGITAL MULTIMETERKYORITSU ELECTRICAL INSTRUMENTSWORKS,LTD.,取扱説明書INSTRUCTION MANUAL

Pagina 2 - 1. Safety Warnings

―20―7. How to use Function Switches7-1 SELECT KeyThis key is to chose the measuring function at Ω/ Diode Check/ Continuity/ function and Current func

Pagina 3 - 3. Specification

―21―8. Auto Power OffAuto power off function operates when about 15minutes passed after power on this instrument.When Auto power off function operates

Pagina 4 - ±1.5%rdg±5dgt (50 / 60Hz)

保 証 書共立製品をお買い上げいただきありがとうございます。保証期間内に通常のお取扱いで万一故障が生じた場合は、保証規定により無償で修理いたします。本書を添付の上ご依頼ください。お名前ご住所 〒お電話番号  ( )−( )−( )◎保証規定をよくお読みください。◎本保証書は日本国内でのみ有効です。◎

Pagina 5

―12―1. Safety WarningsThis instrument has been designed, manufactured and tested according to the following standards.IEC 61010-1 Measurement CAT.Ⅲ 30

Pagina 6 - 4. Instrument Layout

―13―CAUTION● Always make sure to check the Function Selector Switch is setting to the appropriate range before starting measurement.● Do not expose th

Pagina 7

―14―6.000A10.00A600.0μA6000μA60.00mA600.0mA6.000A10.00A600.0Ω6.000kΩ60.00kΩ600.0kΩ6.000MΩ60.00MΩACAResistanceΩ±1.5%rdg±5dgt (50 / 60Hz)±1.8%rdg±5dgt (

Pagina 8

● Standards IEC61010-1 Measurement CAT.Ⅲ 300V, pollution degree 2 / Measurement CAT.Ⅱ 600V, pollution degree 2IEC61010-031IEC61326● Mode of operation

Pagina 9

―16―5. Preparation5-1 Checking Battery VoltageSet the Function Selector Switch to other positions except the OFF position.Battery Voltage is enough if

Pagina 10

(2) Set the Function Selector Switch to " " position.(Then, "AC", "Auto", and "V" symbols are indicated on the

Pagina 11 - 10. Maintenance

(5) Connect the test leads to the circuit under test so the instrument is in the series.(6) Power on the circuit under test.(7) Measured value is indi

Pagina 12 - INSTRUMENTS WORKS, LTD.

(Then, " " and "Ω" symbols are indicated on the display.)Make sure that the "OL." symbol is indicated on the display at